Showing posts with label keV x-ray. Show all posts
Showing posts with label keV x-ray. Show all posts

Monday, June 13, 2011

SACLA X-ray free electron laser sets new record

RIKEN and the Japan Synchrotron Radiation Research Institute (JASRI) have successfully produced a beam of X-ray laser light with a wavelength of 1.2 Angstroms, the shortest ever measured. This record-breaking light was created using SACLA, a cutting-edge X-ray Free Electron Laser (XFEL) facility unveiled by RIKEN in February 2011 in Harima, Japan. SACLA (SPring-8 Angstrom Compact free electron LAser) opens a window into the structure of atoms and molecules at a level of detail never seen before.

The use of ultra high-intensity X-ray free electron laser light to explore the miniature structure of matter, until recently inconceivable, is today transforming how we visualize the atomic world.. By providing much shorter wavelengths and higher intensities than other lasers, XFEL enables researchers to directly observe and manipulate objects on an unrivalled scale, opening new research opportunities in fields ranging from medicine and drug discovery to nanotechnology.

One of only two facilities in the world to offer this novel light source, SACLA has the capacity to deliver radiation one billion times brighter and with pulses one thousand times shorter than other existing X-ray sources. In late March, the facility marked its first milestone with beam acceleration to 8GeV and spontaneous X-rays of 0.8 Angstroms.

Only three months later, SACLA has marked a second milestone. On June 7, SACLA successfully increased the density of the electron beam by several hundred times and guided it with a precision of several micrometers to produce a bright X-ray laser with a record-breaking wavelength of only 1.2 Angstroms (a photo energy of 10 keV). The new measurement far exceeds the previous record of 1.5 Angstroms set in 2009 at the only other operational XFEL facility in the world, the Linac Coherent Light Source (LCLS) in the United States.

With experiments soon to commence and user operations at the facility to begin by the end of fiscal 2011, this new record offers a taste of things to come with SACLA's powerfulbeam, the world's most advanced X-ray free electron laser.

Thursday, October 23, 2008

Powerful x-rays made from sticky tape



Peeling ordinary sticky tape can generate bursts of X-rays intense enough to produce an image of the bones in your fingers.

Seth Putterman and colleagues from the University of California, Los Angeles used a motor to unwind a roll of sticky tape and recorded the electromagnetic emissions. Ripping the tape from its roll at 3 centimetres per second generated X-ray bursts of 15 kiloelectronvolts – each lasting one-billionth of a second, and containing over a million photons.

Putterman admits he is not sure exactly what is going on. "My attitude is to marvel at the phenomenon – all we are doing is peeling tape, and nature sets up a process that gives you nanosecond X-ray bursts."
Charged mystery

Exactly what drives this process is still a mystery, but it is well known that if two surfaces rub over one another, one becomes positively charged and one negatively charged.

In this case, the sticky adhesive becomes positive, and the polyethylene roll negative. This charge difference builds up until an electron jumps from the adhesive to the roll, with enough energy to produce X-rays when it hits the tape.

The strength of the X-rays means that they could be a useful source for X-ray photography.
Sticky tape fusion

Putterman has even loftier ambitions. "The energy in the X-rays is enough to generate nuclear fusion, if it is given to the molecules rather than the electrons," he says. "It's a matter of engineering design, not physics."

Tom Todd, chief engineer of UKAEA Culham Division says, "It is true that the emitted X-ray energies are broadly representative of the electron energies – and that, if you could produce copious quantities of deuterium and tritium [the heavy hydrogen atoms needed for fusion] ions at around 15 keV, in sufficiently high density, they would produce fusion reactions."

However, it is unlikely that all these conditions will be met at the same time, so any power produced from the fused nuclei would be tiny, compared to the power required to unwind the sticky tape.

"It's not unphysical, just uneconomical by a great many orders of magnitude," concludes Todd.

Journal reference: Nature, DOI: 10.1038/nature07378

Monday, January 28, 2008

Ultrafast X-ray study of dense-liquid-jet flow dynamics using structure-tracking velocimetry

Yujie Wang1, Xin Liu2, Kyoung-Su Im1, Wah-Keat Lee1, Jin Wang1, Kamel Fezzaa1, David L. S. Hung3 & James R. Winkelman3

1. X-Ray Science Division, Argonne National Laboratory, Argonne, Illinois 60439, USA
2. Mayo Clinic, Rochester, Minnesota 55905, USA
3. Visteon Corporation, Van Buren Township, Michigan 48111, USA

Nature Physics. doi:10.1038/nphys840

High-speed liquid jets and sprays are complex multiphase flow phenomena with many important industrial applications. Great efforts have been devoted to understand their dynamics since the pioneering work of Rayleigh on low-speed jets. Attempts to use conventional laser optical techniques to provide information about the internal structure of high-speed jets have been unsuccessful owing to the multiple scattering by droplets and interfaces, and the high density of the jet near the nozzle exit. Focused-X-ray-beam absorption measurements could provide only average quantitative density distributions using repeated imaging. Here, we report a novel approach on the basis of ultrafast synchrotron-X-ray full-field phase-contrast imaging. As illustrated in our case study, this technique reveals, for the first time, instantaneous velocity and internal structure of optically dense sprays with a combined unprecedented spatial and time resolution. This technique has tremendous potential for the study of transient phenomenon dynamics.

The X-ray beam is generated from the electron storage ring. The fill pattern shown is the hybrid-singlet mode: a single electron bunch (150 ps long and carrying 15 mA of current) is separated from a longer train of electrons (472 ns long, 94 mA) by a 1.59 mus gap on both sides. The fast shutter absorbs more than 99% of the beam power, and lets the beam through for a few milliseconds at 1 Hz. The sample image is formed on a fast scintillator crystal (LYSO:Ce) and read on a CCD (charge-coupled device) camera via a microscope objective and a mirror at 45° angle. The inset shows the APS undulator-A energy spectrum at 31 mm gap on a logarithmic scale. The fundamental sharp peak at 13.3 keV is 100 times brighter than the harmonics.

Monday, October 29, 2007

Surface heating of wire plasmas using laser-irradiated cone geometries

It's reported on the recent issue of Nature Physics.

Petawatt lasers can generate extreme states of matter, making them unique tools for high-energy-density physics. Pressures in the gigabar regime can potentially be generated with cone-wire targets when the coupling efficiency is high and temperatures reach 2–4 keV. The only other method of obtaining such gigantic pressures is to use the megajoule laser facilities being constructed (National Ignition Facility and Laser MégaJoule). The energy can be transported over surprisingly long distances but, until now, the guiding mechanism has remained unclear. Here, we present the first definitive experimental proof that the heating is maximized close to the wire surface, by comparison of interferometric measurements with hydrodynamic simulations. New hybrid particle-in-cell simulations show the complex field structures for the first time, including a reversal of the magnetic field on the inside of the wire. This increases the return current in a spatially separated thin layer below the wire surface, resulting in the enhanced level of ohmic heating. There are a significant number of applications in high-energy-density science, ranging from equation-of-state studies to bright, hard X-ray sources, that will benefit from this new understanding of energy transport.

LSP modelling of the azimuthal magnetic field structure at the cone tip, 600 fs after the main interaction. A reversed field can be seen on the inside of the wire surface corresponding to the ohmic return current, which is shown on the right picture.

Thursday, April 19, 2007

The crystal melting movie?

As Phy Org web reported, Stanford Synchrotron Radiation Laboratory (SSRL) researchers
have observed the atomic events involved in rapid crystal melting using an intense laser and ultra-fast x-rays.

Sub-Picosecond Pulse Source (SPPS) provides short bursts of x-rays (2 x 10^6 photons in an 80 fs FWHM pulse at 8.9 keV with a 1.5% bandwidth into a 200 um by 400 um spot). The laser pulse (50fs FWHM, 20 mJ @ 800 nm) at the sample, which convolved with the x-ray pulse yields a Gaussian cross correlation of 100 fs FWHM.

The data, published recently in Physical Review Letters, revealed that when their bonds destabilized, the atoms moved apart from each other quickly, as if repelling each other. The semiconductor material had visible melting damage after being struck by the laser.

Wednesday, December 13, 2006

X-Ray Rainbow

via Physics News Update #805

In 1670 Isaac Newton demonstrated the composite nature of sunlight when he sent a carefully collimated sunbeam through a prism, which spread out the light into a rainbow of colors; by sending a beam of single color through a second prism (with no further spreading) Newton showed that the color was not being imposed by the prism but was intrinsic to the light itself. Now physicists using the Advanced Photon Source at Argonne National Lab, in Illinois, have spread out a beam of X-rays (which are, after all, just a more energetic version of visible light) into a rainbow of colors.

Trying to reflect X-rays from a surface is difficult because X-ray wavelengths are some 10,000 times shorter than those for visible light. Glancing reflection of only a few tenths of a degree is normally possible, and even then the beam of X-rays will suffer very little wavelength-dependent spreading. However, another phenomenon, Bragg diffraction, allows for scattering of X-rays from a crystal through large angles; in this case the incoming X-rays scatter not merely from a top layer of atoms in the crystal but from numerous atomic planes. Furthermore, if the atomic planes are not parallel to the crystal surface the diffracted X-ray beam will be spread out prismatically into a range of component wavelengths (or colors).

In the Argonne experiment an incoming beam of 9-kiloelectronvolt X-ray photons with angular spread of only 1 micro-radian (two-tenths of an arcsecond) was backwards scattered and spread out into an X-ray rainbow with an angular dispersion of 230 micro-radians (see figure).

Argonne physicist Yuri Shvyd'ko (shvydko@aps.anl.gov, 630-252-2901) says that his rainbow is not just a novelty but will have many practical applications in X-ray optics. These include compression of X-ray pulses in time and the development of X-ray monochomators (which fashion X-ray beams of pure wavelength, or color) and much higher-resolution X-ray spectrometers.

Shvyd'ko et al., Physical Review Letters, 8 December 2006

Wednesday, December 06, 2006

2D imaging conical x-ray spectrograph

We are using a Von Hamos x-ray spectrograph to observe the x-ray imession from laser cluster interaction, which only provides the spectral information. I think we can use this novel x-ray crystal spectrograph to measure the spectral resolved 2-D image in our experiment.

Extreme luminosity imaging conical spectrograph

S. A. Pikuz, T. A. Shelkovenko, M. D. Mitchell, K. M. Chandler, J. D. Douglass, R. D. McBride, D. P. Jackson, and D. A. Hammer
Laboratory of Plasma Studies, Cornell University, 439 Rhodes Hall, Ithaca, New York 14853

A new configuration for a two-dimensional (2D) imaging x-ray spectrograph based on a conically bent crystal is introduced: extreme luminosity imaging conical spectrograph (ELICS). The ELICS configuration has important advantages over spectrographs that are based on cylindrically and spherically bent crystals. The main advantages are that a wide variety of large-aperture crystals can be used, and any desired magnification in the spatial direction (the direction orthogonal to spectral dispersion) can be achieved by the use of different experimental arrangements. The ELICS can be set up so that the detector plane is almost perpendicular to the incident rays, a good configuration for time-resolved spectroscopy. ELICSs with mica crystals of 45×90 mm2 aperture have been successfully used for imaging on the XP and COBRA pulsed power generators, yielding spectra with spatial resolution in 2D of Z pinches and X pinches. ©2006 American Institute of Physics

Rev. Sci. Instrum. 77, 10F309 (2006)

Tuesday, October 10, 2006

Compound Refractive x-ray Lenses (CRLs)

The compound refractive x-ray lenses (CRLs) are used to focus and collimate hard x rays, and image objects using hard x rays. The lenses have been experimentally shown to operate in energy ranges from 4 to 80 keV, at focal lengths as small as 5 cm, with numerical apertures of 10-3 or better. These operational ranges can be further extended.

The main principle behind compound refractive lenses (CRLs) is an ability of a group of thin lenses to greatly shorten the focal length. A series of N lenses with small apertures is used to achieve both one- and two-dimensional focusing and imaging at x-ray photon energies, where refractive imaging has previously been thought to be impossible due to the weak refraction of x rays. Note that the refractive index for x-rays is less than 1.

Therefore, unlike visible light optics which will cause visible rays to diverge, the concave lens will focus x-ray photons. Among the lenses we offer are cylindrical, spherical and 1- and 2- dimensional parabolic units.

From Adelphi Technology Inc.

Wednesday, August 30, 2006

Obtaining the Xe(L) spetra successfully

The laser system ran very well today. The front end output a laser beam with about 26 mJ energy. After the Prometheus amplifier, the energy reached about 360 mJ as energizing 25 kV high voltage. Today the total shots is 1218, no misfire happened. The filament was shut down in the beginning, I could hear the click from the filament relay, after turn on again, the problem disappeared.

Because the nozzle was changed, I adjusted the timing delay for optimizing the Xe(L) outputs. Alex took many spectra from the target side.